|
| RTC1 RELAY SPECIFICATION |
| All
data are at 20°C ambient temperature unless otherwise noted. |
| |
|
|
|
|
|
| |
|
|
|
|
|
| Miniature high current PCB relay. |
|
|
|
|
| |
|
|
|
|
|
| Covers a broad range of automotive applications. |
|
|
|
| |
|
|
|
|
|
| The relays are lead free / RoHS compliant. |
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
RTC1 |
|
| Available Standard Types |
| RTC1 |
Reflow Type |
reflow solderable |
125°C |
max. ambient temperature |
|
| |
|
*
The standard "R" types have a vent-hole in the cover (Letter
T appended) |
| Special Features available: ( see nomenclature page) |
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| Available Coil Options |
| Coil Resistance |
Coil Inductance |
Nominal Power |
Operate Voltage |
Operate Power |
Release Voltage |
| 160
Ω |
376 mH |
0.900
W |
6.5 V |
0.264
W |
0.5 V |
| 110
Ω |
265 mH |
1.309
W |
5.5 V |
0.275
W |
0.5 V |
| 225
Ω |
506 mH |
0.640
W |
7.7 V |
0.264
W |
0.5 V |
| |
|
|
|
|
|
| |
|
|
|
|
|
| ITEM |
SPECIFICATION |
|
Contact Arrangement
|
1 Form
C / 1 Form A / 1 Form U (double-make contact)
|
|
Contact Material
|
AgSnO2 Alloy
|
|
Contact Resistance
|
Typical 3 mΩ (max 50mΩ at 6 VDC
1A)
|
|
Contact Rated Load
|
25A at
14VDC Motor load (Locked Rotor)
|
|
Max. Switching Current/ Voltage
|
30A at
16VDC
|
|
Max. Continuous Current at 20 °C
|
30A at
14VDC for 10minutes
|
|
Min. Switching Current (recommended)
|
1A at 12VDC
|
|
Dielectric Strength
|
500VAC
for 1 minute (between coil and contact)
|
|
500VAC for 1 minute (between open contacts)
|
|
Insulation Resistance
|
Min 100MΩ (at 500VDC)
|
|
Operate Time
|
typical 4 ms (at 12VDC/ 20 )
|
|
Release Time
|
typical 2 ms with no diode parallel to coil
|
|
Shock
resistance
|
False Operation
|
Min 98m/s2 ( 10G) :Shock wave
11ms
|
|
Endurance
|
Min 980m/s2 (100G) :Shock wave
6ms
|
|
Vibration resistance
|
False Operation
|
Min 43m/s2
( 4.4G) at 10 to 500Hz
|
|
Endurance
|
|
Mechanical Life (no load)
|
Min 10×106 Operations(300 cycles/minute)
|
|
Electrical Life at rated load
|
Min 0.1×106 Operations(1 sec. ON/ 9 sec. OFF)
|
|
Ambient Temperature range
|
-40°C to 125°C max.,Max 85%RH
|
|
Weight
|
Approx.
10g
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| TECHNICAL REFERENCE DATA FOR THE RTC1-160 RELAY |
| Contact Resistance of the N/O contact |
Contact Resistance of the N/C contact |
|
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
|
Operate Time
|
|
|
Release Time
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| Operating Voltage Range of the RTC1 with a
160 Ω coil |
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
| Please note, that this diagram |
|
|
|
|
| |
|
|
|
|
| shows the Operate Voltage range |
|
|
|
|
| for coil at ambient temperature |
|
|
|
|
| |
|
|
|
|
| and the Maximum Voltage |
|
|
|
|
| is either 16 V or the voltage
that |
|
|
|
|
| over time brings the coil to the |
|
|
|
|
| max. allowed temperature. |
|
|
|
|
| |
|
|
|
|
| No Load Current considered. |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| TECHNICAL REFERENCE DATA FOR THE RTC1-160 RELAY |
|
Coil temperature rise of the RTC1 with 160
Ω coil
|
|
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
|
Over current limit
|
|
|
Operate
and Release time
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
|
Contact
voltage drop
|
| |
|
|
|
|
|
| |
|
|
|
|
|
|
increasing current |
|
|
|
|
| |
decreasing current |
|
|
|
|
This
diagram shows
the voltage drop over current
for the NO contact during
the increase of the current
and during the decrease |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| External Dimensions / Wiring Diagram / PCB
Pin Layout |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| Packaging specification |
| Standard Tube Packaging |
50 relays
per tube, 20 tubes per box (1000 relays per box) |
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
| Notes: |
| |
|
|
|
|
|
| For further
information, please contact Taiko device Techno. |
| |
|
|
|
|
|
| Disclaimer: |
| |
|
|
|
|
|
| The above information
is for information only and with no responsibility, not binding
and can be changed any time. |
| Taiko Device Techno cannot be held responsible
for typos, or misprints. |
|
|
|
|
|
|